Maintenance and troubleshooting – ProForm PFST12020 User Manual

Page 7

Advertising
background image

Inspect and properly tighten all parts of the stepper
regularly. To clean the stepper, use a damp cloth and
a small amount of mild detergent. Never use abra-
sives or solvents. Keep liquid away from the con-
sole, and keep the console out of direct sunlight.

CONSOLE TROUBLESHOOTING

If the console does not function properly, or if the dis-
play becomes faint, refer to assembly step 4 on page
5 and replace the battery.

If the console still does not function properly, locate
the Reed Switch (24) under the Frame (1) (see the
inset drawing). Hold down the left Pedal Leg (6) so
that the Magnet (26) is level with the Reed Switch.
Slide the Reed Switch forward or backward slightly,
and then exercise for a moment to see whether the
console functions properly. If necessary, readjust the
position of the Reed Switch.

7

24

26

6

1

6

1

MAINTENANCE AND TROUBLESHOOTING

Advertising