Specifications, Pressure drop (psi) flow (gpm) plde36 plde48, Table 1 - recommended de manufacturers – Pentair Modular DE Filter PLDE48 User Manual

Page 4: Table 2 - filter specifications, Normal operation backwash mode, Figure 1a – dimensions in inches (mm), Figure 2 – pressure drop curve, Figure 1b – piping connections

Advertising
background image

4

Inlet

Outlet

7-13/16

(198)

9-3/16

(233)

18.5
(470)

18.5
(470)

36

(914)

45.25

(1150)

0

5

10

15

20

20

40

60

80

100

Pressure drop (PSI)

Flow (GPM)

PLDE36

PLDE48

SPECIFICATIONS

FIGURE 1A – Dimensions in inches (mm)

Table 1 - Recommended DE Manufacturers

Johns Manville

Celite 545™

GREFCO, Inc.

Decalite 4200™

Eagle-Picher Minerals, Inc.

Celatom™

Table 2 - Filter Specifications

PLDE36

Filter Area sq. ft. (m

2

)

36 (3.3)

Lbs. (kg) of DE Used

5.4 lbs. (2.4 kg.)

Maximum Flow Rate gpm (L/m)

72 (273)

Max. Operating Pressure psi (kPa)

50 (345)

Max. Continuous Water Temperature F(C)

104° (40°)

PLDE48

Filter Area sq. ft. (m

2

)

48 (4.5)

Lbs. (kg) of DE Used

7.2 lbs. (3.3 kg.)

Maximum Flow Rate gpm (L/m)

96 (363)

Max. Operating Pressure psi (kPa)

50 (345)

Max. Continuous Water Temperature F(C)

104° (40°)

One half pound of DE will fill a one pound coffee can.

FIGURE 2 – Pressure Drop Curve

Water Inlet pumped
from pool

Water Outlet
To Pool

Water Inlet pumped
from pool

Water Outlet
To Separation Tank

Flow out to drain if
separation tank
is not used.

FIGURE 1B – Piping Connections

Normal Operation

Backwash Mode

Advertising