Ac characteristics, Gsm/dcs/pcs power amplifier cgy2014tt – Philips CGY2014TT User Manual

Page 6

Advertising
background image

2000 Oct 16

6

Philips Semiconductors

Product specification

GSM/DCS/PCS power amplifier

CGY2014TT

AC CHARACTERISTICS
V

DD

= 3.5 V; T

amb

= 25

°

C; measured on the Philips demoboard (see Fig.8).

Notes

1. The device is adjusted to provide nominal load power into a 50

load. The device is switched off and a 6 : 1 load

replaces the 50

load. The device is switched on and the phase of the 6 : 1 load is varied 360 electrical degrees

during a 60 seconds test period.

2. The power amplifier can be matched to PCS and or DCS/PCS operation through optimization of the matching circuit.

3. Isolation can be improved to

20 dBm (typical value) with a pin diode switched in the DCS output matching.

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

Low band: GSM power amplifier

P

i(LB)

input power

2

0

+2

dBm

f

RF(LB)

RF frequency range

880

915

MHz

P

o(LB)(max)

maximum output power

see Figs 3 and 4

34.5

35

dBm

η

LB

efficiency

see Fig.3

50

55

%

P

o(LB)(min)

minimum output power

V

DD

= 0 V; P

i(LB)

= 0 dBm

35

dBm

N

RX(LB)

output noise in RX band

P

i(LB)

= 0 dBm

f

RF

= 925 to 935 MHz

117

dBm/Hz

f

RF

= 935 to 960 MHz

129

dBm/Hz

H2

LB

2nd harmonic level

P

i(LB)

= 0 dBm

35

dBc

H3

LB

3rd harmonic level

P

i(LB)

= 0 dBm

35

dBc

Stab

LB

stability

P

i(LB)

= 0 dBm; note 1

60

dBc

High band: DCS/PCS power amplifier; note 2

P

i(HB)

input power

2

3

5

dBm

f

RF(HB)

RF frequency range

for DCS operation

1710

1785

MHz

P

o(HB)(max)

maximum output power

see Figs 5 and 6

32

32.5

dBm

η

HB

efficiency

see Fig.5

38

40

%

P

o(HB)(min)

minimum output power

V

DD

= 0 V; P

i(HB)

= 3 dBm

32

dBm

α

HB

high band isolation when
low band is operating

V

DD(LB)

= 3.5 V; P

i(LB)

= 0 dBm;

V

DD(HB)

= 0 V; P

i(HB)

= 3 dBm;

note 3

0

dBm

N

RX(HB)

output noise in RX band

P

i(HB)

= 3 dBm

121

dBm/Hz

H2

HB

2nd harmonic level

P

i(HB)

= 3 dBm

35

dBc

H3

HB

3rd harmonic level

P

i(HB)

= 3 dBm

35

dBc

Stab

HB

stability

P

i(HB)

= 3 dBm; note 1

60

dBc

Advertising