Panasonic EY6506 User Manual

Page 9

Advertising
background image

- 9 -

Bolt Tightening Conditions

M6, M8, M10, M12 x 25 mm (1") Standard bolt

M10 x 25

mm

High tensile bolt

(Bolt size : Millimeters)

Tightening time (Sec.)

Tightening

torque

M10 x 25 High tensile bolt

100

(87)

200

(174)

300

(260)

400

(347)

500

(434)

600

(521)

700

(608)

800

(695)

900

(782)

0

M12

M10

M8

M6

0.1 0.25 0.5 1.0 2.0 3.0 4.0

k f-cm

(in-lbs)

2) Tightening time

Longer tightening time results in

increased tightening torque. Excessive

tightening, how ever, adds no value and

reduces the life of the tool.

3) Different bolt diameters

The size of the bolt diameter affects

the tight ening torque.

Generally, as the bolt diameter

increases, tightening torque rises

4) Tightening conditions

Tightening torque will vary, even

with the same bolt, according to

grade, length, and torque coefficient

(the fixed coefficient indi cated by the

manufacturer upon produc tion).

Tightening torque will vary , even

with the same bolting material (e.g.

steel), accord ing to the surface fin-

ish.

Torque is greatly reduced when the

bolt and nut start turning together.

5) Socket play

Torque is lowered as the six-sided

configu ration of the socket of the

wrong size is used to tighten a bolt.

6) Switch (Variable speed control trigger)

Torque is lowered if the unit is used

with the switch not fully pulled out.

7) Effect of Connecting Adaptor

The tightening torque will be lowered

through the use of a universal joint or

a connecting adaptor.

Washer

Washer
Spring washer

Steel plate

thickness 10 mm (3/8")

Bolt

Nut

Tightening conditions

* The following bolts are used.

Standard bolt: Strength type 4.8

High tensile type 12.9
Explanation of the strength type
4.8

Bolt tensile strength 60 k f/mm

2

(85,000psi)

Bolt yield point

(80% of tensile strength)

48 k f/mm

2

(68,000psi)

Advertising