Hardware description, Block diagram, Functional description – Philips ISP1301 User Manual

Page 12: Pcf8584 i, C-bus controller, Pc parallel to i, C converter, Hc, dc and otg core logic interface connector, This block provides functions of the i, C master to access the isp1301 i

Advertising
background image

Philips Semiconductors

ISP1301 USB OTG Transceiver Eval Kit User’s Guide

UM10028_1

© Koninklijke Philips Electronics N.V. 2003. All rights reserved.

User’s Guide

Rev. 1.0—February 2003

12 of 18

6. Hardware description

6.1. Block

diagram

Figure 6-1 shows the block diagram of the ISP1301 evaluation board.

ISP1301

OTG TRANSCEIVER

AUDIO INTERFACE

(L/R SPEAKER LINE IN,

MIC PRE-AMP OUT)

PC PARALLEL-TO-I

2

C

CONVERTER

PCF8584 I

2

C-BUS

CONTROLLER

POW ER MANAGER

ISA

PARALLEL

DP, DM, ID, V

BUS

I2

C

-BU

S (SC

L,

SD

A, AD

R

, I

N

T

)

DP

, DM,

ID

V

BUS

HC, DC and OTG CORE

LOGIC INTERFACE

CONNECTOR

(to the ISP1362 FPGA or

Phone FPGA)

CORE INTERFACE (OE, VP, VM, RCV,

SPEED, SUSPEND, RESET, V

DD_LGC

)

FPGA

INTERFACE

V

BAT

mini-AB Receptacle

V

ex

t

4-PIN I

2

C

HEADER

Figure 6-1: Block diagram of the ISP1301 evaluation board

6.2. Functional

description

A brief description of each function module is given in the following sections.

6.2.1. PCF8584

I

2

C-bus controller

This block provides functions of the I

2

C-bus to the 8-bit parallel-bus converter. It can connect to the Philips

ISP1362 or ISP1161x ISA interface board, or any other generic 8-bit microprocessor interface through a 40-wire
IDE cable. The PC or other microprocessor can service the interrupt from the ISP1301 and access the registers of
the ISP1301 through this interface.

6.2.2.

PC parallel to I

2

C converter

This interface provides an alternative method to access the ISP1301 I

2

C interface through the PC. The PC needs to

emulate software I

2

C master to access the ISP1301 I

2

C slave.

6.2.3.

HC, DC and OTG core logic interface connector

This interface provides connection to a Host Controller (HC), Device Controller (DC) or On-The-Go (OTG)
core logic. This interface is used during OTG system-level evaluation or during compliance testing.

Advertising