4 troubleshooting guide – Panasonic EY6506-U1 User Manual

Page 5

Advertising
background image

(Refer to WIRING CONNECTION DIAGRAM)

4 TROUBLESHOOTING GUIDE

< TROUBLE >

< CHECK >

< REMEDY >

Does not operate.

<CHECK BATTERY PACK.>

NO Replace battery pack.

If no less than 12V DC is available across the (+) and (-) terminals,

the battery pack is OK.

NOTE:

The battery pack is sold separately as an optional accessory.
See the nearest sales dealer for details. The battery pack has a
limited life.
The pack should be replaced if;

- after being charged for the rated charging time the battery voltage

is less than 12V DC or the usable time is extremely short.

- the battery leaks. Check battery for leaks and terminals for

corrosion.

OK

<CHECK TERMINAL CONNECTIONS BETWEEN MAIN UNIT

NO Repair contacts.

AND BATTERY PACK.>

Check for proper terminal contacts.

OK

<CHECK SWITCH BLOCK.>

NO Contacts in switch block

(See WIRING CONNECTION DIAGRAM.)

are defective.

Check continuity between following terminals.

Replace switch & FET

* Inspection of the forward / reverse selection switch.

block.

When switch handle is depressed all the way:

- There should be 0

between (A) - (D) , and between (B) - (C) ;

when switch lever is set to forward side.

- There should be 0

between (A) - (C) , and between (B) - (D) ;

when switch lever is set to reverse side.

* Inspection of the brake.

When switch handle is not depressed:

- There should be 0

between (A) - (B) .

OK

<CHECK MOTOR BRUSH.>

NO Replace motor

A. Check the condition of carbon brush.

brush assembly.

(Do not touch between brush holder and holding spring.)

B. There should be 0

between motor lead wire and

terminal of brush holder.

OK

<CHECK MOTOR ROTOR.>

NO Replace motor

Check the condition of rotor if there is any wear, crack and deformation.

rotor assembly.

OK

<CHECK MOTOR STATOR.>

NO Replace motor

Check the condition of motor case if there is any crack and deformation.

stator.

5

EY6506-U1

Advertising