System Configuration

Decide what kind of system to form. Determine the num-
ber of the external devices, the connection form, and the
mode (p. 14 Unit Modes and Signal Flow).

d

Connections

Connect the components to the unit.

d

Settings

Configure the following settings:

• Modes (pp. 14 to 17)
• Input line assignment (if using the SUB OUT jack) (p.

18)

• Output line assignment to MULTI IN/LINE IN.(p. 19)

d

Sticking a Label (p. 26)

Stick the supplied label on each component.

d

Adjusting the Input and Output Levels (pp. 29 to 31)

Adjust the input and output levels with the knobs on the
front panel.

d

Attaching/detaching the acrylic cover (p. 28)

Attach the acrylic cover on the unit front panel to prevent
wrong operation.

INSTALLATION

■

Work Flow

■

Before Installation

Caution:

Contact your dealer for installing the unit.
Be sure to toggle the power off and unplug the unit from
the receptacle before installation. Follow the safety
instructions.

●

Power Connection

Connect the power cord by any of the following methods,
making sure to provide a breaking device in each case.

(1) Connect the power cord to the power control unit.
(2) Install the unit near a receptacle and connect the power

cord to the receptacle via a breaking device. The
breaking device should be installed near an operator.

(3) Connect the power cord to a circuit breaker in a panel

board that has a contact distance of 3.0 mm or more.
Use a circuit breaker that will interrupt each circuit of
the main power supply (except a ground-protective
conductor).

●

Installation Place

• Install the unit out of direct sunlight and away from out-

lets of heated air. Installation in a humid, dusty or shaky
place may cause trouble.

• Keep a distance between this unit and a transformer,

dimmer, image device, CRT monitor, etc. as much as
possible. Failure to do this may cause induction noise.

●

Rack Mounting

Keep the temperature in the rack below 45 °C . Failure to
do this may cause damage to internal components.

●

Grounding the Unit

Ground the unit by the grounding terminal at the rear side.
If the devices are connected in unbalanced connections,
synchronize each grounding potential as follows:

• Synchronize the power supply phases.
• Synchronize the power supply lines.
• Connect each device's grounding terminal or chassis

with a thick grounding wire of each device.

Failure to do this may cause induction noise.

Note:

If the unit is placed more than 10 m away from

other external devices, grounding the unit near an unbal-
anced external device is recommended.

●

Condenser Microphone

• When using a condenser microphone, connect it to an

external device.

• Do not connect external devices supplying phantom

power, as it may damage the unit.