Preliminary specification

70 W high efficiency power amplifier
with diagnostic facility

TDA1562Q; TDA1562ST;

TDA1562SD

Fig.5 Behaviour as a function of temperature.

handbook, full pagewidth

class-H

maximum output

voltage swing

diagnostic

output

status I/O: high

status I/O: open

MGL266

class-B

0

HIGH

LOW

status I/O

output

HIGH

MID

LOW

120

145

Tj (

°

C)

150

160

100

LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134).

Notes

1. When operating at V

P

> 16 V, the output power must be limited to 85 W at THD = 10% (or minimum load is 6

).

2. T

j

is a theoretical temperature which is based on a simplified representation of the thermal behaviour of the device.

T

j

= T

c

+ P

×

R

th(j-c)

, where R

th(j-c)

is a fixed value to be used for the calculation of T

j

. The rating for T

j

limits the

allowable combinations of power dissipation P and case temperature T

c

(in accordance with IEC 60747-1).

SYMBOL

PARAMETER

CONDITIONS

MIN.

MAX.

UNIT

V

P

supply voltage

operating; note 1

18

V

non-operating

30

V

load dump; t

r

> 2.5 ms; t = 50 ms

45

V

I

OSM

non-repetitive peak output current

10

A

I

ORM

repetitive peak output current

8

A

V

sc

short-circuit safe voltage

18

V

T

stg

storage temperature

55

+150

°

C

T

amb

ambient temperature

40

°

C

T

j

junction temperature

note 2

150

°

C

P

tot

total power dissipation

60

W