Panasonic CR Relays User Manual

Cr relays, Specifications, Features

Advertising
background image

CR

SPECIFICATIONS

TWIN POWER SILENT

AUTOMOTIVE RELAY

CR RELAYS

18.5

.728

24.6

.969

17.0

.669

mm

inch

RoHS Directive compatibility information

http://www.nais-e.com/

FEATURES

• Silent
Noise has been reduced by
approximately 20 dB, using our own
silencing design.

• Twin (1 Form C

× 2)

Forward/reverse motor control is possible
with a single relay.

• Sealed construction
• Simple footprint enable ease of PC

board layout

Normally
Open

Common

Normally
Closed

Coil

Coil

Contact

Coil

#1 This value can change due to the switching frequency, environmental conditions,

and desired reliability level, therefore it is recommended to check this with the
actual load.

Characteristics

Arrangement

1 Form C

× 2

Contact material

Ag alloy (Cadmium free)

Initial contact resistance (Initial)
(By voltage drop 6 V DC 1A)

Typ. 6 m

Ω (N.O.)

Typ. 9 m

Ω (N.C.)

Contact voltage drop

Max. 0.2V (at 10 A)

Rating

Nominal switching
capacity

N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC

Max. carrying current

35 A for 2 minutes,

25 A for 1 hour

(12 V, at 20

°C

68

°F

)

30 A for 2 minutes,

20 A for 1 hour

(12 V, at 85

°C

185

°F

)

Min. switching capacity

#1

1 A 12 V DC

Expected life
(min. operations)

Mechanical (at 120 cpm)

Min. 10

7

Electrical

Resistive load

Min. 10

5

*

1

Motor load

Min. 2

×10

5

*

2

Min. 10

5

*

3

Nominal operating power

640 mW

Max. operating speed
(at nominal switching capacity)

6 cpm

Initial insulation resistance*

4

Min. 100 M

Ω (at 500 V DC)

Initial breakdown
voltage*

5

Between open
contacts

500 Vrms for 1 min.

Between contacts
and coil

500 Vrms for 1 min.

Operate time*

6

(at nominal voltage)(at 20

°C

68

°F

)

Max. 10 ms (initial)

Release time*

6

(at nominal voltage)(at 20

°C

68

°F

)

Max. 10 ms (initial)

Shock resistance

Functional*

7

Min. 100 m/s

2

{10G}

Destructive*

8

Min. 1,000 m/s

2

{100G}

Vibration resistance

Functional*

9

10 Hz to 100 Hz,

Min. 44.1 m/s

2

{4.5G}

Destructive*

10

10 Hz to 500 Hz,

Min. 44.1 m/s

2

{4.5G}

Conditions for
operation, transport
and storage*

11

(Not freezing and
condensing at low
temperature)

Ambient
temperature

–40

°C to +85°C

–40

°F to +185°F

Humidity

5% R.H. to 85% R.H.

Mass

Approx. 12.5g

.44 oz

Remarks

*

1

At nominal switching capacity, operating frequency: 1s ON, 9s OFF

*

2

N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating
frequency: 0.5s ON, 9.5s OFF

*

3

At 20A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF

*

4

Measurement at same location as “Initial breakdown voltage” section

*

5

Detection current: 10mA

*

6

Excluding contact bounce time

*

7

Half-wave pulse of sine wave: 11ms; detection: 10

µs

*

8

Half-wave pulse of sine wave: 6ms

*

9

Detection time: 10

µs

*

10

Time of vibration for each direction;

X, Y, direction: 2 hours
Z direction: 4 hours

*

11

Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere
(110

°C

230

°F

).

X

Y

Z

TYPICAL APPLICATIONS

• Power windows
• Auto door lock
• Electrically powered sunroof
• Electrically powered mirror, etc.

ORDERING INFORMATION

Contact arrangement

Coil voltage(DC)

1 Form C

× 2

Standard packing: Carton(tube package) 32pcs. Case: 800pcs.

12 V

Ex. CR

2

12 V

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Advertising
Table of contents