Repair flow chart (continued) – Philips V30 User Manual
Page 78

Repair Flow Chart (Continued)
9
Go to cover page
107T5
24. Selftest
check pin24
1.no H/V sync & IF cable pin5 floating
- show msg.
2.H/V sync exist & IF cable pin5 to ground
- normal
3.H/V sync non-exist & IF cable pin5 to gnd
-power saving
4.After 1892&1893 pressed on, then power on
(1895) with IFcable pin5 =L
-factory mode
5.After 1892&1893 pressed on, then power on
(1895) without IFcable pin5=H
-burn in mode
check idle status
sda=pin25=hi
scl=pin26=hi
25,26. DDC bus
check idle status
sda=pin32=hi
scl=pin31=hi
31,32. IIC bus
check key Power, Ok, LF,
Brightness and contrast keys
23. Keypad
check
output from 0V to 5V
4. Rotation
check 3891~3894
EEPROM
check 7802 pin 7
Low
: write enable
Hi
: write disable
check
7802
M24C16
7501
TDA9112A
7331
NT6812K
check
output from 0V to 5V
29. ABL
30. H-linearity
check
output from 0V to 5V
78