Accessories for HLE and HLEZ

Automation

33

Parker Hannifin GmbH

Electromechanical Division

Mechanical limit switch

The switching button complies with DIN EN 50047. The contacts satisfy the safety requirements in accordance
with EN 60947-5-1 by virtue of forced opening (positively driven).

60

5

51

51

30

60

4,4

20

85
100

ma

x.

6

5

35

Electrical limit switch

There are two variants of inductive proximity sensors:

Integrated sensors:

These are installed in a T groove on the upper side of the profile (standard with flange plate)

External sensors:

These are attached to the outside of the profile (and are used for carriage version with bar
T/F or for the corrosion-resistant version V)

The sensors are either activated by a tripping plate fastened to the side of the flange plate (external sensors) or by
a switch lug attached to the underside of the flange plate (integrated sensors – can only be used for the HLE).

Integrated sensors:

LA

L

S

A

H

B

LED

G

Connection diagram

A 2

3

1

load

PNP-

normally closed

contact

bn

bk

bu

switch
lug

Model / size

A

B

G

H

L

LA

S

HLE80 / HLE100

12

8

M4

12

40

34

8

HLE150

12

8

M4

12

52

46

10

Technical data

DC electrical data

Switching distance

1.8-2.2 mm

Voltage range

10 - 30 V DC

Switch hysteresis

3 - 15 %

Supply current

< 10 mA

Repeatability

± 3 %

Maximum switching
current

150 mA when T = 25°C

Ambient temperature

-25°C - +70°C

Voltage drop

< 3.5 V at a switch current of

150 mA

Type of protection

IP67

Max. switching frequency

1 kHz

Cable length

6 m

Connection cables

3 x 0.14 mm

2

Advertising