Pentair 2000 Series User Manual

Page 6

Advertising
background image

P/N 075122

6

Rev. C 7-6-01

7.

Use garden hose to rinse down filter elements until all debris has been flushed from tank. Then screw drain plug on
backwash line on models with Separation Tank.

8.

Unscrew wing nut; remove washer and unclip air vent tube from holding wheel. Remove holding wheel.

9.

Lift out filter elements and scrub each element with a soft brush. If elements are coated with scale, it will be
necessary to brush with a mild solution of muriatic acid (10 parts water to 1 part muriatic acid). Rinse elements
with water.

10. Remove manifold and inspect for damage. Replace rotor O-ring & lubricate as needed.

11. Replace clean elements in manifold sockets; notch on element will guide it to proper position. All elements are

interchangeable.

12. Replace holding wheel over center rod; place washer over rod and turn holding wheel until elements spread to

widest gap. Replace washer, then screw wing nut on rod. Do not tighten nut beyond finger tight. Be sure to
clip air vent tube back into slot on holding wheel. Clean vent tube screen cap of any debris.

13. Remove rubber O-ring and clean both O-ring and channel. Lubricate O-ring with a non-water soluble grease or

silicone lubricant and replace O-ring in channel.

14. Clean the inside surface of the tank lid where it seals against the O-ring. Place lid on tank; push down on lid to seat

in place.

15. Replace the clamping ring. Engage the head of the T-bolt into the slotted bracket and tighten the adjustment knob.

(Hand tighten only.)

16. To restore to the filter cycle, refer to the operating and cleaning instructions of the filter model involved. When

winterizing, ensure that all water is removed from the lower internal portion of the filter.

PRESSURE DROP CURVES

D.E. FILTERS

D.E. Filter - 2000 Series

Head Loss Curve

SMBW-2024

SMBW-2036

SMBW-2048

SMBW-2060

SMBW-2072

SM-2024

SM-2036

SM-2048

SM-2060

SM-2072

Advertising