Sw1-6/7 clock mode, Sw1-8 rdl function, Sw1-6/7 clock mode sw1-8 rdl function – Patton electronic 1082/F User Manual
Page 15
                                    Advertising
                                    
                                        
                                    
                                
                                 
15
SW1-6/7 Clock Mode.
Use Switches S1-6 and S1-7 to configure the
1082 or Model 1082/144 for internal, or receive recover clock mode.
Note
Placing SW1-6 and SW1-7 in the OFF mode performs reset of
the hardware/software.
SW1-8 RDL Function.
Use Switch S1-8 to allow Model 1082/F to enter
the Remote Digital Loopback diagnostic test when requested to do so by 
the far end Modem. For example, when switch S1-8 is set to “ON”, it will 
enter RDL mode when requested to do so by the remote Model 1082.
S1-6
S1-7
Description
ON
ON
Internal clock (DEFAULT)
ON
OFF
Recover clock
OFF
ON
Network clock
OFF
OFF
Hardware/software reset
ON
Respond to RDL (DEFAULT)
OFF
Response to RDL disabled