SERVICE INSTRUCTIONS

























CLEARANCE TO COMBUSTIBLES






ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60Hz circuit with a properly grounded

outlet is required. Preferably, the heater will be on a

dedicated circuit. Other appliances on the same circuit

may cause the circuit breaker to trip or the fuse to blow

when the heater is on operation. The unit comes standard

with a 6’ (1828mm) long three wire cord exiting from the

rear of the fireplace. Plan the installation to avoid the use

of an extension cord. If an extended cord must be used, it

must be a minimum 16 AWG three wire with grounding

type plug connector and rated no less than 1900 Watts.

Back………………2”/50.8mm

Sides……………..6”/156.4mm

Floor……………..0”/0mm

Top……………….24”/610mm

WARNING: Electrical outlet wiring

must comply with local building

codes and all other applicable

regulations to reduce the risk of

fire, electrical shock and injury.

WARNING: Do not use this

fireplace if any part of it has been

under water. Immediately call a

qualified service technician to

inspect the fireplace and replace

any part of the electrical system if

necessary.

ELECTRICAL SPECIFICATIONS

Voltage………………120 VAC/60Hz

Total Amps…………..11.3 Amps

Total Watts…………..1345 Watts

Heater Ratings………1200 Watts

WARNING: Disconnect power

before attempting any

maintenance or cleaning to

reduce the risk of fire, electrical

shock or personal injury

REPLACING LIGHT BULBS

This fireplace uses two clear 120 Volt, 60 Watt, E-12

socket base light bulbs (small base, chandelier candle

type).The 60 Watt bulbs are located under the log

set/ember bed. For convenience, if one of the bulbs

burns out, it may be a good idea to replace both of the

light bulbs.

1. Turn off power to the unit by unplugging the power

cord.

2. Let fireplace cool if it has been operating.

3. Open the front door by pulling the handle.

4. Remove the two screws that secure the log set in

position.

WARNING: Do not exceed 60

Watts per bulb. Use of higher

rated bulbs may result in a fire

causing property damage and

personal injury.

3

5. Remove the two screws of the front baffle and

take them out.

6. Examine the bulbs to determine which one

needs to be replaced.

7. While holding the socket, unscrew the defective

bulb(s).

8. Install the new light bulb(s) by holding the socket

and screwing them in.

9. Reinstall the baffle

log set and screen. Follow

the above procedure in reverse order.