Operating instructions, Figure a – Procom V50HYLC User Manual

Page 6

Advertising
background image

Operating Instructions

This section provides easy step by step instructions for operating your fireplace.

1. Make sure the unit is unplugged from the power source (see warning on page 6)

2. Plug the heater into a 15AMP/120volt outlet. If the cord does not reach, you may use an extension

cord rated for a minimum of 1900 watts.

To access the controls, open the door of the fireplace at the front of the unit (see Figure A).

Figure A

A. PROPER WAY TO INSTALLING HANDLE
















B. MAIN ON/OFF SWITCH
The on/off switch supplies power to all fireplace functions (heater/flame).
C. HEATER ON/OFF SWITCH 1
The HEATER ON/OFF SWITCH 1 supplies power to the heater fan and the heater element.
NOTE:

When switched ON, the heater fan and the heater element will operate. But it gives an

output of 600W. It is just half of the total power.

D. HEATER ON/OFF SWITCH 2
The HEATER ON/OFF SWITCH 2 supplies power to the heater element, and the remaining
voltage to the heater.
NOTE: When switched ON, the heater fan and the heater element will still operate. But it gives
an another output of 600W. Then, the heater will arrive its total value of 1200W. The heater fan
and the heater element will not operate if SWITCH 2 is ON but SWITCH 1 is OFF.
E. INSTRUCTIONS FOR POWER

Figure B

5

Insert handle’s threading tip

into the hole, turn slightly the

handle to proper position and

make threading tip get through

the hole, screwing the nut

supplied. See Figure B