10 biasing of the mr element, 1 mr head resistance and temperature measurement – Philips TDA5360 User Manual

Page 12

Advertising
background image

1998 July 30

Philips Semiconductors

Objective Specification, Revision 2.2

Pre-Amplifier for Hard Disk Drive with
MR-Read / Inductive Write Heads

TDA5360

12

10 BIASING OF THE MR ELEMENT

This preamplifier has been designed for SAL and GMR elements. Programming bit GMR in Reg. 01 select either a SAL
range (LOW) or a GMR range (HIGH).
By programming bit PORI in Reg. 01, the user can program either a constant current bias (LOW) or a constant power
bias (HIGH) for the MR element. The value of the current/power is programmed on 5 bits via Reg. 02.

If bit PORI in Reg. 01 is HIGH, a constant power bias is maintained accross the MR element.

The power is defined as :

Pw = R

MR

* I

MR

2

, where Pw is constant over temperature and process.

In power bias mode, two power ranges are possible :

For SAL heads

1.5mW to 9.25 mW

in steps of 0.25mW

For GMR heads

375uW to 2.3 mW

in steps of 0.0625mW

Note :

whatever Power programmation is used, the I

MR

current flowing into the MR element will be within the min-

max range given below.

If bit PORI in Reg.01 is LOW, then the biasing scheme shall revert to constant current instead of constant power.
I

MR

is then constant over temperature and process.

In current bias mode, two current ranges are possible :

For SAL heads :

4 to 10.2 mA in steps of 0.2 mA

For GMR heads :

3 to 6.1 mA in steps of 0.1 mA

Note :

In GMR mode, I

MR

current is guaranted up to 5.1mA

6.1mA can be reached under certain supplies/Rmr conditions.

10.1

MR Head Resistance and Temperature Measurement

By programming RANGE0,RANGE1 bits in Reg. 08, the user can select either a Rmr measurement or a Temperature
measurement (junction temperature).

Setting DIGON bit HIGH launch a digitazation
The settling time of the digitization operation is less than

TBD

µ

s.

A 5 bit code is then available in Reg. 08, as long as DIGON stays HIGH,
Setting DIGON bit LOW, reset the 5 bit code.

In case of Rmr measurement, the user have access to two Rmr range by programming RANGE0 and RANGE1 bits.

In case of Temperature too high condition (T > 140

o

C), during a Temperature measurement, a Fault is triggered on FLT

line and a error code is available in Reg. 07.

Advertising