Installation s – Pentair Small Underwater Pool Lights SunLite LTC User Manual

Page 5

Advertising
background image

INSTALLATION
S

unLite

®

LTC Lamp Housing Installation

(Refer to Figure 1, below)

Burn hazard. This light should never be

energized while laying face down on the pool deck.

Installation of a 12 Volt transformer is required when

installing the 12 Volt model of this light. The transformer

must be located:

• at least 10’ from the pool wall,

• installed near a grounded, 3-prong, 120V, GFCI

protected outlet. If you do not have a GFCI protected

outlet, have a qualified electrician install one.

Do not use a 3-prong adapter. The adapter voids the

grounding of the system.

Do not cut the grounding pin.

Do not use an extension cord! Purchase a light with a

longer cord.

1. Be sure the power is off.

2. Place lamp housing on the deck above the niche.

Feed the cord through the back of the lamp housing

and to the conduit box. Make sure that there is

enough cord to allow the fixture to be placed on the

deck for re-lamping.

3. Make connections in the conduit box (be sure to fol-

low code requirements!). Connect the supply circuit

grounding wire (green, green and yellow, or bare

copper) to the green ground conductor from the light

fixture. Connect the line supply wire (the black or

’hot’ wire) to the black wire from the light fixture.

Connect the neutral (white) supply wire to the neutral

(white) wire from the light fixture.

4. Coil the remaining cord in the back of the niche and

place the lamp housing in the niche. The mounting

tab on the bottom of the lamp housing must be in the

notch at the bottom of the niche.

5. Fasten the lamp housing into the niche with the

captive leader screw at the top of the lamp housing

(use a No. 2 Phillips screwdriver). Tighten this screw

securely (20 inch-pounds torque) to insure good

electrical bonding.

NOTICE: The leader screw in the face ring may be

recessed.

NOTE: Do not try to loosen the strain relief (cord nut) on

the back of the lamp housing; the cord is not detachable

from the lamp housing. Attempting to loosen the strain

relief will damage the lamp housing assembly, void the

warranty and may cause an electrical shock hazard if the

pool bonding is not connected and functioning correctly

(see “General Safety”, Page 2).

5

Sufficient cord to allow fixture to
be put on the deck for relamping

Brass conduit

Pool wall

Fixture

18” Min.

Low level
probe

To service

To fixture

To
service

8” Min.

8” Min.

Fixture removed
for relamping

4 Ft. Min.

Junction box

Max. water
level

Figure 1: Lamp Housing Installation

Advertising