Troubleshooting

Use the following troubleshooting information to resolve possible problems with your SuperFlo pump.

WARNING — RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.

Improperly installation will create an electrical hazard which could result in death or serious injury
to pool users, installers, or others due to electrical shock, and may also cause damage to property.

1. If you are not familiar with your pool filtering system and/or heater:

a. Do NOT attempt to adjust or service without consulting your dealer, or a qualified pool

technician.

b. Read the entire Installation & User’s Guide before attempting to use, service or adjust the

pool filtering system or heater.

Note: Turn off power to unit prior to attempting service or repair.

Problems and Corrective Actions

Problem

Corrective Action

FAILURE TO PUMP

Pump Will Not Prime — to much air

Check suction piping and valve glands on any suction gate valves.

Secure lid on pump strainer pot and make sure lid gasket is in place.

Check water level to make sure skimmer is not drawing air.

Pump Will Not Prime — not enough water

Make sure suction lines, pump strainer, and pump volute are full of water.

Make sure valve on suction line is working and open, (some systems do not have valves).

Check water level to make sure water is available through skimmer.

Pump strainer clogged

Clean pump strainer pot.

Pump strainer gasket defective

Replace gasket.

REDUCED CAPACITY and/or HEAD

Air pockets or leaks in suction line

Check suction piping and valve glands on any suction gate valves.

Pump Will Not Prime — to much air

Secure lid on pump strainer pot and make sure lid gasket is in place.

Check water level to make sure skimmer is not drawing air.

Clogged impeller

Turn off electrical power to the pump.

Remove the clamp that holds the volute to the seal plate.

Slide the motor and seal plate away from the volute.

Clean debris from impeller.

If debris cannot be removed, complete the following steps.

(1) Remove left hand thread anti-spin bolt and O-ring.

(2) Remove, clean and reinstall impeller.

(3) Reinstall anti-spin bolt.

Reinstall diffuser and quad ring.

Reinstall motor and seal plate into volute.

Reinstall clamp around seal plate and volute and tighten securely.

Pump strainer clogged

Clean suction trap.