Philips 107B7 User Manual

Page 70

Advertising
background image

17” CDT Color Monitor 107B7

70

2.7.4 Monitor status information

• Self-test feature -

“CHECK SIGNAL CABLE” message appears when video cable

is

disconnected.

• Out of scan range -

“FREQUENCY IS OUT OF RANGE” appears when input H-sync

or V-sync out of range.

• Resolution & H/V input -

Shown in OSD menu “EXTRA CONTROLS”.



2.7.5 Power connector

• AC socket 3-pin IEC-320-C13, at rear side.



2.7.6 Video input connector/Video cable

• 1.5m non-detachable fly-in video cable with D-Sub 15 pin male blue connector, pin assignment of D-Sub:


Pin

Function

1 Red

video

2 Green

video

3 Blue

video

4 GND
5 Self

test

6 Red

GND

7 Green

GND

8 Blue

GND

9

+5V (Supply from PC for DDC circuit)

10 Sync

GND

11 GND
12 DDC

serial

data

13 H-sync
14 V-sync
15 DDC

serial

clock

• H-sync line impedance must be within 50 ~ 70Ω (TDR measurement).

• V-sync line impedance should be within 40 ~ 70Ω (TDR measurement).

• RGB signal lines must be 75Ω ± 5% coaxial.

• R, G, B coaxial shield must connect to D-Sub metal shell.



3. Front Of Screen Performance


3.1 CRT characteristics