Raid 5 function of the exten, Raid 5 function of the extension unit, Setup/cancel the raid 5 function – Panasonic WJ-HD316 User Manual

Page 128

Advertising
background image

128

Summary of the RAID 5 function (Redundant
Arrays for Independent Disks, independent
data disks with distributed parity blocks)

RAID level 5 regards 3 or more drives as one drive, and it is
possible to read data by attaching error correction data
even though one of the drives is broken automatically. (It is
impossible to read data if 2 or more drives are broken.)
RAID level 5 requires a minimum of 3 drives to implement.
When using the RAID function, logical disk size of the
extension unit will be as below.
Logical disk size = Smallest size of the disk among the
disks in the extension unit x (Number of the disks in the
extension unit - 1)

Important:

• When connecting two extension units or more with this

unit, it is impossible to connect the extension unit with
the RAID 5 function and the one without the RAID 5
function at the same time.

• When the RAID 5 function is used, it is impossible to

use two hard disks in this unit. The recorded pictures in
those disks will not be deleted.

RAID 5 Function of the Extension Unit

Setup/cancel the RAID 5 function

Do the following to set or cancel the RAID 5 function with an
extension unit.
Refer to the operating instruction of the extension unit for
further information.

z Make sure that the power of this unit and all of the

extension units to be connected are OFF.

x To set the RAID 5 function, set the mode switch of the

extension unit to "RAID 5".
To cancel the RAID 5 function, set the mode switch of
the extension unit to "SINGLE".

c Make sure that the HDD POWER switch of the extension

unit is "ON".

v Turn the power of the extension unit on.

b Turn the power of this unit on.

→ The "HDD DISK MENU" will be displayed automati-

cally after the system check when the hard disk
configuration has been changed such as when an
extension unit is newly connected.

Important:

• When the RAID 5 function is set or canceled, all data on

each hard disk of the extension unit will be deleted.

• When turning the power on, turn the power of the exten-

sion unit first, and then turn the power of this unit on.
Otherwise, the extension unit may not work correctly.

Advertising