Plumbing & water flow, Warning, Plumbing connections – Pentair HP 600 User Manual

Page 18: Internal automatic bypass

Advertising
background image

The heat pump in equipped with
a internal "Automatic Bypass"
valve. A variable rate spring
valve is used to regulate the wa-
ter flow through the heat ex-
changer. Steady flow will be de-
livered over a wide range of flow
rates. This automatic valve can
handle a maximum flow rate of
90 gallons per minute.

The automatic valve will com-
pensate for flow loss due to nor-
mal filter debris accumulation or
changes if flow due to valving
and other conditions.

See chlorinator
placement guidelines.

PLUMBING CONNECTIONS

Filtered Water “IN” on the LEFT front.
Heated Water "OUT" on the RIGHT front.
The plumbing inlets are "slip" p.v.c. pipe that will accept
a 2 inch p.v.c. glue fitting. The pipe is left plain so you
can adapt to your needs. Use p.v.c. cleaner to prime the
fitting and pipe. Use a quality medium body p.v.c. glue.
FOR PUMPS UP TO 2 H.P. OR 90 G.P.M. MAX.
SEE PAGE 19 FOR LARGER WATER PUMPS.

Automatic Bypass Valve

Variable Rate Self Adjusting

up to 90 G.P.M.

PLUMBING & WATER FLOW

INTERNAL AUTOMATIC BYPASS

See mandatory chlorinator placement
and install of the loop & check valve.

Water

Pump

Filter

Chlorinator or

Chemical Feeder

Heater

Chlorinator Loop & 2 lb. Chem.

Resistant Check Valve

WATER IN

WATER

OUT

1. PUMP
2. FILTER
3. HEATER
4. LOOP & CHECK
5. CHLORINATOR
6. RETURN TO POOL

Warning

No Chemicals In

Skimmer !!

IN

OUT

Special

Compression Fitting

Sacrificial Chemical Protec-

tion Piping

Marine Grade

Cupronickel

Heat Exchanger

Encased in

Closed Cell Foam

Free Flow

Flexible

Water Inlets

WARNING