Operator control panel stand-alone set-up – Pentair IntelliPro VS-3050 User Manual

Page 9

Advertising
background image

Operator Control Panel

Stand-Alone Set-Up

(no controller or appliance communicating with IntelliPro

VS-3050

)

The IntelliPro

VS-3050

must be primed before starting for the first time. It may take several

minutes depending on water depth, pipe size, and length. Note: IntelliPro

VS-3050

will prime

itself when used in a fl ooded suction system.

Caution –

to avoid permanent damage to IntelliPro

VS-3050

, before starting the pump,

fill the housing strainer with water so that the pump will prime correctly. If there is no
water in the strainer, the pump will not prime.

Never run the pump dry.

Running dry may damage seals, causing leakage and fl ooding.

Do not add chemicals to the system directly in front of pump suction. Adding undiluted
chemicals may damage the pump and will void the warranty.

Release all pressure from pump and piping system prior to servicing.
Never tighten or loosen the clamp while the pump is operating.

1. Press the stop button if the pump is running.
2. Disconnect the communication cable from the pump.
3. Close the gate valves in suction and discharge pipes.

Priming the pump for the
fi rst time or after service

Important: Follow these
steps before removing
pump lid and priming

7

IntelliPro

VS-3050

Quick-Start Guide

Advertising