Data Structure Reference 5-7
C O D E 9 3 I N F O
The CODE93INFO data structure contains scanner configuration
information about Code 93 bar codes. To read these values,
applications call scnGetCode93Info; to set these values, they
call scnSetCode93Info.
typedef struct _Code93Info
{
unsigned char uchEnable;
unsigned char uchLength1;
unsigned char uchLength2;
} CODE93INFO;
Field Description
uchEnable
Enable/disable the ability to scan Code 93 bar
codes.
Default: SCN_DISABLE
uchLength1
uchLength2
Specifies lengths (including check digits) for
Code 93 bar codes. You can specify one or two
lengths, a range of lengths, or that any length is
valid. Enter values as follows:
Option
uchLength1
uchLength2
1 Length
Value
0
2 Lengths
Higher Value
Lower Value
Range Min.
Value
Max. Value
Any length 0
0
Default: 4 (uchLength1) and 55 (uchLength2).