Example of system configuration

$

When the distance between the ROP and the pan/tilt control panel is more than 10 meters

The distance between the ROP and the pan/tilt control panel can be extended up to a maximum of about 1000 meters on the
following condition using the provided cable (refer following specifications) and/or equivalent cables. (Prepare the cables of
required length.)

• Up to 50 meters:

Use the recommended AC adaptor for the power supply of the pan/tilt control panel.

• More than 50 meters: Supply DC 12V to the ROP and the pan/tilt control panel from the recommended AC adaptor.

In this case, it is not necessary to connect +12V IN.

Specifications for provided cable

Ferrite core

Ferrite core

Use the twist pair cables.

Connector used

Japan Aviation Electronics Industry, Ltd.
Connector: D02-29PF-N-F0
Contact:

D02-22-26P-PKG100
(For AWG 26 to 28)

Case:

DA-C4-J10

Connector used

Japan Aviation Electronics Industry, Ltd.
Connector: D02-29SF-N-F0
Contact:

D02-22-26S-PKG100
(For AWG 26 to 28)

Case:

DA-C4-J10