background image

Troubleshooting (No Power/Dead Unit) Part 2

Is

there 3.3V at

pin 6 of connector P7 when the

TV is plugged into

the AC line?

Reconnect

A1 and Disconnect

connector A52.

Do the AC relays click after

the TV is plugged into

the AC line?

If cable between connectors K1 and A1 is OK,

Replace the K board

Continue from

Previous slide

NO

NO

NO

Yes

Yes

Yes

Replace

The P board

Disconnect

connector A1.

Do the AC relays click after

the TV is plugged into

the AC line?

Replace

The A board

If cable between connectors GS52 and

A52 is OK, Replace the GS board