Panasonic EYFLA2A User Manual

Page 11

Advertising
background image

- 11 -

• You can select from 30 torque clutch

settings (1 to 30).

• Use figures from the Tightening Torque

Chart to guide your selection of torque
clutch setting. (See the following tighten-
ing torque chart)

. Press the OK button to accept the select-

ed torque clutch setting.

• The control panel will stop flashing and

light up.

CAUTION:

• You must press the OK button in order

for the selected setting to take effect.

• Be sure to verify the new value after

changing the setting. (See page 11.)

Tightening Torque Chart (for Reference
Use)

The values illustrated on this chart were mea-
sured under the conditions described below
and are provided for reference purposes.
Actual tightening torque varies with ambient
conditions (the particular bolt being tightened,
hardware being used, method of holding the
bolt in place, etc.).

0

10

20

30

40

50

60

EYFLA1 (M6)

EYFLA2 (M6)

EYFLA1 (M8)

EYFLA2 (M8)

EYFLA3 (M8)

EYFLA3 (M10)

N • m

1 2 3 4 5 6 7 8 9 10 111213 1415 16171819202122 232425 26272829 30

Measurement conditions
• Temperature: Room temperature (0°C/68°F)

Using the Interval Set
• The interval set operates to prevent the tool

from operating after it automatically stops as
a result of the torque control function, even if
the switch is engaged.

1. Set the tool to configuration mode.

(See page 10.)

. Press the interval set button.

• The control panel will begin flashing.

Display: The number 0 flashes on and off.
Battery indication lamp: The middle bar

of the battery flashes on and off.

Display

Battery indication lamp

3. Press the

and

buttons to set the

desired time.

Buttons

Display

Seconds

30

3

1

0.1

0

Off

4. Press the OK button to accept the select-

ed setting.

• The control panel will stop flashing and

light up, and the torque clutch setting
will be displayed.

CAUTION:

• Be sure to verify the new value after

changing the setting.

Initializing All Settings

Factory settings

• Torque clutch setting: “F” (torque con-

trol function off)

• Interval setting: 0 (off)

• This section explains how to revert all tool

settings to their default values at the time of
shipment from the factory.

• The error display will be turned off.
1. Set the tool to configuration mode.

(See page 10.)

. Press the format button.

• The control panel will begin flashing.

Display: The letter “F” flashes on and off.
Battery indication lamp: The upper and

lower bars of the battery flash on and off.

Display

Battery indication lamp

Advertising