Auxiliary Port Specifications
45
Section 7:
Auxiliary Port
Specifications
The 6-pin minicircular auxiliary interface is used for connect-
ing the printer with auxiliary equipment such as a Auto Cutter.
Pin assignments are as follows:
Uses 5v logic @ 5mA - All signals are active low.
Cut signal - Output - Cut now.
Printer Busy - Output - Printer is Printing or
Cutter Position - Input - Cutter is in normal
position (Ready). Low will keep printer from
Remote Pause - Input - Will keep printer from
NOTE: Cut signal output is enabled when “Present between every label”,
mode is active. Rewinder is set to "NO" in printer driver preferences.