A. Command Line Interface

A-24

March

2002

6300-A2-GB20-00

show bridge

Minimum Access Level: Operator
Command Mode: Standard

Displays the bridge configuration and forwarding database.

Sample

show bridge

display:

Bridging – disabled

Spanning tree – enabled
Configured aging timeout: 300 seconds

Filtering database entries:

MAC addr action interface timeout (sec.)

xx:xx:xx:xx:xx:xx xxxxxxx xxxxxx xxxxxxxxxxxx

NOTES:

– Action can be discard or forward.

– Timeout can be Permanent, the number of seconds left before the entry is aged out

and goes away, or <1 (less than a second).

show config

Minimum Access Level: Operator
Command Mode: Standard

Sample

show config

display:

syslog {enabled

|

disabled}

eth1 frame {DIX

|

802.3}

proxy ARP eth1 {enabled

|

disabled}

proxy ARP dsl1 {enabled

|

disabled}

basic NAT {enabled

|

disabled}

NAPT {enabled

|

disabled}

or

NAT disabled

*

DHCP server {enabled

|

disabled}

DHCP relay {enabled

|

disabled}

bridging {enabled

|

disabled}

IP routing {enabled

|

disabled}

IP multicast {enabled

|

disabled}

packet processing {enabled

|

disabled}

dsl1 1483 encapsulation {LLC

|

VC Muxing}

autologout {enabled

|

disabled}

PPPoE client {enabled

|

disabled}

telnet {enabled

|

disabled}

telnet login required {enabled

|

disabled}

* NAT disabled only appears when both forms of NAT are disabled.

show console

Minimum Access Level: Operator
Command Mode: Standard

Displays either

console enabled

or

console disabled

.

Table A-17. Show Commands (2 of 10)