Caution, Outdoor installation, Outdoor vent kit – Pentair MiniMax NT LN User Manual

Page 18: Important

Advertising
background image

P/N 472089

Rev. E 4-19-05

18

OUTDOOR INSTALLATION

For outdoor installation with an exhaust grill, the heater must be placed in a suitable area on a level, noncombustible surface. Do not
install the heater under an overhang with clearances less than 3 feet from the top of the heater. The area under an overhang must be
open on three sides.

IMPORTANT!

• In an outdoor installation it is important to ensure water is diverted from overhanging eves with a proper

gutter/drainage system. The heater must be set on a level foundation for proper drainage.

• Under certain conditions, “heavy rains or unusually high winds”, it may be necessary to install an outdoors

vent. In this situation, use Outdoor Vent Kit, P/N 460424, (see below).

• This unit shall not be operated outdoors at temperatures below -20

o

F.

CAUTION

If installing the heater next to or near an air conditioning unit or a heat pump, allow a minimum of 36 in.
between the air conditioning unit and the heater.

(Outdoor Shelter Installation in Canada, see

page 15

)

Section III. Installation

VENTING GUIDELINES

OUTDOOR INSTALLATION

Must be at least 3 ft. above any forced
air inlet located within a 10 ft. radius.

Vent Termination:

Must be located 4 feet away from the building wall
openings, and at the following distances away from
any door, window, or gravity air inlet:

4 ft. below,
4 ft. horizontally

Chec

k local b

uilding codes

for setbac

k requirem

ents

.

Force

Air Inlet

Property Line

4'

4'

4'

3'

SIDE VIEW

Building

Window

Heater

(side view)

Exhaust Grill

(Vent)

4 ft.

4 ft.

Figure 13.

GASKET

SCREWS (6)

METAL FLANGE

SCREWS (6)

GASKET

EXHAUST GRILL

Figure 14.

Figure 15.

OUTDOOR VENT KIT

1. Remove the six (6) retaining screws from the old exhaust grill and discard the screws, gasket, and exhaust grill as shown in

Figure 14

.

2. Install the Outdoor Vent Kit, (P/N 460424), as shown in

Figure 15

. Make sure the holes in the gasket, metal flange of the main vent

assembly, and heater cover are aligned before securing into place using the six (6) screws provided in the Outdoor Vent Kit.

Advertising