6) external control by rs-232c, 96 adjustments, 1 interface – Pioneer RMF-V4011R User Manual

Page 97

Advertising
background image

96

ADJUSTMENTS

(6) External Control by RS-232C

As Multi projection unit is equipped with a RS-232C port, various controls and, white balance and convergence adjustments

can be performed by an external computer.

By programming software ,it is possible not only to adjust White Balance,Convergence but to save and control the adjust-

ment data of each source.

1 Interface

1]Connector

D-sub 25-pin

2]Pin assignment

[3]Baud rate

4800 bps (1200, 2400, 9600, 19200 bps can also be

selected)

[4]Data format

Start:1-bit

Data:8-bit

Parity:0 (No parity)

Stop:1-bit

[5]Connection

COMPUTER

FG 1

TXD 2

RXD 3

CTS 5

GND 7

1 FG

2 RXD

3 TXD

5 CTS

7 GND

[6]Protocol

Multi projection unit from computer

Up to 3 commands possible

stx

stx

stx

ID

ID

ID

etx

etx

etx

Straight cable

TXD 3

RXD 2

CTS 8

GND 5

2 RXD

3 TXD

5 CTS

7 GND

1 FG

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

ARGUMENT

ID : 2-Byte(ASC ll)COMMAND : 3-Byte(ASC ll)

stx=02h etx=03h

Multi projection unit

Multi projection unit

COMPUTER

(IBM PC)

*

ARGUMENT : 3-Byte(ASC ll)

Note : * In case of the numeral direct command

PIN No.

1

2

3

5

7

Symbo;

FG

RXD

TXD

CTS

GND

Signal Name

Frame Ground

Received Data

Transmitted Data

Clear To Send

Signal Ground

Advertising
This manual is related to the following products: