Quick reference data – Philips TDA8586 User Manual

Page 3

Advertising
background image

2001 Jul 23

3

Philips Semiconductors

Preliminary specification

Power amplifier with load detection and
auto BTL/SE selection

TDA8586

QUICK REFERENCE DATA

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

V

P

operating supply voltage

8.0

−

18

V

I

q(tot)

total quiescent current

V

P

= 14.4 V, SE mode

−

140

170

mA

I

stb

standby supply current

V

P

= 14.4 V

−

1

100

µ

A

G

v

voltage gain

SE mode

25

26

27

dB

BTL mode

31

32

33

dB

Bridge-tied load application

P

o

output power

V

P

= 14.4 V; R

L

= 4

Ω

THD = 0.5%

14

15

−

W

THD = 10%

17

21

−

W

THD

total harmonic distortion

f

i

= 1 kHz; P

o

= 1 W;

V

P

= 14.4 V; R

L

= 4

Ω

−

0.05

0.15

%

V

OO

DC output offset voltage

V

P

= 14.4 V; R

L

= 4

Ω

;

mute condition

−

10

20

mV

V

P

= 14.4 V; on condition

−

0

100

mV

V

n(o)

noise output voltage

R

s

= 1 k

Ω;

V

P

= 14.4 V

−

100

200

µ

V

Single-ended application

P

o

output power

V

P

= 14.4 V; R

L

= 4

Ω

THD = 0.5%

4

4.5

−

W

THD = 10%

5

6

−

W

THD

total harmonic distortion

f

i

= 1 kHz; P

o

= 1 W;

V

P

= 14.4 V; R

L

= 4

Ω

−

0.08

0.15

%

V

OO

DC output offset voltage

V

P

= 14.4 V; R

L

= 4

Ω

;

mute condition

−

10

20

mV

V

P

= 14.4 V; on condition

−

0

100

mV

V

n(o)

noise output voltage

R

s

= 1 k

Ω;

V

P

= 14.4 V

−

80

150

µ

V