Troubleshooting (controls), Thermostat circuit board – Pentair Pool and SPA Heater PowerMax User Manual

Page 9

Advertising
background image

Rev. G 1-22-04

P/N 471048

9

Operation (contd.)

HEAT (HEAT)
The heat light is on any time the thermostat has
signaled a call for heat which initializes the ignition
safety firing circuit -- the light comes on to indicate
successful firing of the main burners.

SERVICE (SERVICE)
The service light is off during normal operation of
heater. The light only comes on if a problem with a
control has occurred or when the heater is first
firing. The problem must be investigated by the
serviceman prior to attempts to fire the heater again.

The diagrams that follow give examples of
troubleshooting a malfunctioning heater using the
assistance of the indicator lights.

TROUBLESHOOTING (CONTROLS)

Example of troubleshooting with the assistance of the indicator lights.

PWR

TSTAT

RMT

PRESS

SRVE

HI TEMP

TFUSE

GAS VALVE

MV

MV

IGNITION MODULE

IND

GND

VAL

MV

HEAT

CLOSE IF

NO MV

THERMOSTAT

RELAY

REMOTE

PRESS

TFUSE

HI TEMP

LIMIT SWITCHES

BREAKER

CIRCUIT

TRANSFORMER

INCOMING

LINE VOLTAGE

THERMOSTAT CIRCUIT BOARD

LIMIT SWITCHES

HI TEMP

NO MV

CLOSE IF

THERMOSTAT CIRCUIT BOARD

TRANSFORMER

LINE VOLTAGE

INCOMING

PWR

CIRCUIT
BREAKER

TSTAT

RMT

RELAY

THERMOSTAT

REMOTE

PRESS

SRVE

PRESS

HI TEMP

MV

TFUSE

TFUSE

HEAT

IGNITION MODULE

IND

GND

VAL

GAS VALVE

MV

MV

WATER AT SELECTED TEMPERATURE.... NORMAL OPERATION

THERMOSTAT CALLING FOR HEAT - PUMP OFF(NO PRESSURE) BLOCKS FIRING

NORMAL OPERATION

SYMBOL TABLE

LED LIT

LED OFF

SWITCH OR DEVICE
OPEN CIRCUIT
(BLOCK CURRENT)

SWITCH OR DEVICE
CLOSED CIRCUIT
(PASS CURRENT)

THERM

AUX

PRESS

HEAT

POWER

SERVICE

FRONT PANEL LEDS

FRONT PANEL LEDS

HEAT

PRESS

AUX

THERM

SERVICE

POWER

OR POOL/OFF/SPA THERMOSTAT SELECT SWITCH OFF.... NORMAL OPERATION