ThermalFlo Installation and User’s Guide

Multiple Heat Pump Connections

All plumbing on multiple heat pump installations must be done in parallel see Figures 9 and 10. An equal flow
of water to each heat pump is important for optimum operation.
NOTE: It may be necessary to adjust water pressure switch if a unit is installed below the water
level. See

page 20

for details on when and how to adjust the pressure switch.

Each heat pump allows a maximum flow rate of 125 gpm and requires a minimum of 30 gpm.

24 inches min. clearance around evap.

Extend12" past
end heater inlet
for hydraulic
balancing

Extend12" past
end heater inlet
for hydraulic
balancing

Pool Pump

Flow Meter

Minimum

2" PVC Pipe

2" PVC Pipe

Flow Meter

To Pool

OPTIONAL

2" Check Valve Bypass

Check Valves are
optional on heater inlets
but will help system
balancing

24"

Figure 9.

Two Heat Pump Plumbing Layout

24 inches min. clearance around evap.

Extend12" past
end heater inlet
for hydraulic
balancing

Extend12" past
end heater inlet
for hydraulic
balancing

Pool Pump

Flow Meter

Minimum

3" PVC Pipe

2" PVC Pipe

Flow Meter

To Pool

3" Ball Valve Bypass

Check Valves are
optional on heater inlets
but will help for system
balancing

24"

2" PVC

Pipe

2" PVC

Pipe

2" PVC

Pipe

3" PVC Pipe

3" PVC Pipe

Figure 10. Four Heat Pump Plumbing Layout