Pentair ThermalFlo User Manual

Page 22

Advertising
background image

14

ThermalFlo Installation and User’s Guide

Connecting the ThermalFlo to the IntelliTouch

®

or EasyTouch

®

Load Center

To connect the ThermalFlo cable to the Personality Board in the IntelliTouch or EasyTouch Load Center:

1. Turn off the main system power before making any connections.

2. Unlatch the front door spring latche(s), and open the front door of the IntelliTouch or EasyTouch

Load Center.

3. Loosen the two retaining screws from the top of the control panel and lower the control panel down

to access the Personality Board.

4. Run a UL approved conductor cable from the ThermalFlo to the Load Center.

5. Route the cable up through the low voltage raceway located on the left of the Load Center to the

Personality Board, see Figure 13.

6. Insert the ThermalFlo cable plug onto the gas heater terminal connector, located on the left side of

the Personality Board.

7. If the heat pump is used in conjunction with a gas heater, use a 520403 Dual Heater Relay Kit. Plug

the heat pump relay connector onto the SOLAR Terminal on the top center of the Personality Board.
Follow the Dual Heater Relay Kit instructions for further set-up details.

8. Lift the control panel up into position and secure with the two screws.

9. Connect the cable from the IntelliTouch or EasyTouch Load Center to the heat pump remote control

terminals using ¼ in. “Fast-On” Spade connectors, see Figure 12 on the previous page.

TEMP. SENSORS HAVE NO POLARITY.

TEMP. SENSORS HAVE NO POLARITY.
RED/BLK WIRES ARE INTERCHANGEABLE.

RED/BLK WIRES ARE INTERCHANGEABLE.

BLK
GRN
YEL
RED

Figure 13.