DIAGNOSTIC FLASH CODES

The diagnostic flash codes for your scooter are designed to help you perform basic troubleshooting quickly

and easily. A diagnostic flash code flashes from the status LED in the event one of the conditions listed

below develops.

NOTE: Your scooter will not run unless the flash code condition is resolved and the scooter has been

turned off then turned back on.

What if all the systems on my scooter seem to be “dead”?

n Make certain that the key is in the “on” position.

n Check that the batteries are fully charged. See VI. “Batteries and Charging.”

n Push in the main circuit breaker reset button. See V. “Your Scooter”

n Make certain that both battery harnesses are firmly connected to the electronics module and to the

battery terminals. See IX. “Disassembly and Assembly.”

n Make sure that the front-to-rear harness is firmly connected to the electronics module. See IX.

“Disassembly and Assembly.”

n Check the fuses. See XI. “Care and Maintenance” for fuse replacement.

n Be sure the power down timer feature hasn’t been activated. See VII “Operation.”

What if the motor runs but my scooter does not move?

n With the key turned to the “on” position, check the status LED. If the LED flashes three times, pauses

briefly, then flashes two times, this is the manual freewheel lever code meaning your scooter is in

freewheel mode.

n When the manual freewheel lever is pulled up, the brakes are disengaged and all power to the transaxle

is cut.

n Push down the manual freewheel lever to restore normal operation to your scooter See V. “Your Scooter.”

X . B A S I C T R O U B L E S H O O T I N G

FLASH CODE

CONDITION

SOLUTION

n n n n n

Batteries are too low to operate the
Maxima or the charger is operating.

Charge batteries or unplug the charger power
cord from the electrical outlet.

n n

Controller is hot; the Maxima seems
to be losing power.

Shut down your Maxima for several minutes
to allow the controller to cool.

n n n n

Wigwag fault; your throttle control
levers are not responding.

Call your authorized Pride Provider for
assistance.

n n n n n

The manual freewheel lever is in the
(up) freewheel position.

Turn the Maxima key to the off position,
then push the manual freewheel lever to the
(down) drive position, restart your Maxima.

n n n n n n

The Maxima is operating with the
charger attached.

Unplug the charger cord from the charger
power cord receptacle.