Replacement

E

NGLISH - 31

Maintenance

J

Replacement procedure

Q

Removing and replacing the lamp unit

1. Use a Phillips-head screwdriver to loosen the 1

lamp unit cover fixing screw on the back of the
projector until the screws turn freely, and remove
the lamp unit cover.

Slide the lamp unit cover to the buttons and pull to
remove.

2. Use a Phillips-head screwdriver to remove the

3 lamp unit fixing screws.

3. Hold the handles of the lamp unit and pull the used

lamp unit gently from the projector.

4. Hold the handle of the new lamp unit and replace it

in correct direction.

5. Press in the lamp unit until it clicks and make sure

the unit is installed securely.

6. Tighten the 3 lamp unit fixing screws securely with

a Phillips-head screwdriver.

7. Attach the lamp unit cover and tighten the 1 lamp

unit cover fixing screw securely with a Phillips-
head screwdriver.

Slide the lamp unit cover to the hinge side and push
in to attach securely.

Make sure the fan electric power connector of the
lamp unit cover is inserted securely to the projector’s
connector.

J

Before replacing the ACF

Wait until the cooling fan stops and t

urn off the

POWER

switch of the projector in proper way.

Disconnect the power cord from the wall outlet.

Contact an Authorized Service Center to purchase a replacement ACF (ET-ACF100).

J

When to replace the ACF

The ACF unit is consumable product and effects on ventilation. The FILTER indicator will inform you of the
replacement timing. You can check the remaining amount of the ACF unit in REMAINING FILTER of STATUS
in PROJECTOR SETUP menu.

Lamp unit cover
fixing screw

Lamp unit cover

Handle

Handle

Lamp unit screws

Lamp unit screws

Fan electric power
connector

Replacing the Auto Cleaning Filter (ACF)