Operation of the testboard, Power supply, D.c. power from a power supply – Panasonic PAN4570 User Manual

Page 6

Advertising
background image

CLASSIFICATION
Einstufung

No.
DS-Eval4570-2400

REV.

C

SUBJECT
Thema

EvalBoard PAN4570

PAGE
Seite

6 of 20

CUSTOMER’S CODE
EvalPAN4570

PANASONIC’S CODE

DATE
Datum

06.11.2006

European Technology Center

Panasonic Electronic Devices (EUROPE) GmbH

APPROVED

genehmigt

CHECKED

geprüft

DESIGNED

Erstellt


4. OPERATION OF THE TESTBOARD

If not already done please follow the basic setting up instructions as in

Chapter 2

Check if the jumper plugs are set as indicated in Figure 2. The functions of the jumpers
are as follows:

jumper

ame

function

to set as in Figure 2

A

Vcc for position A

do not care

B

Vcc for module at position B*

do not care

C

Vcc for module at position C*

yes

D

Vcc for module at position D*

do not care

JP2

5Vdc feed to Slots A, B, C, D**

no

JP3

Vcc setting 2.1-2.7-3.4V;
see Table 2

no for
Vcc=2.7Vdc default

JP4

Vcc setting 2.1-2.7-3.4V;
see Table 2

yes for
Vcc=2.7Vdc default

JP7

Vcc regulator output feed
to A, B, C, D

yes

(Table 1)

* Position C is used as an example, position B or D could be used as well.
An amperemeter for measuring module current can be inserted instead of the jumper
** +5Vdc supply (independent on JP3 and JP4 settings) option is provided for application
demos. The +5Vdc supply is NOT used on PAN4570 carrierboard.

Check if the port switches S1 near to the COM2 connector for RS232 are all set to off
position except the selected UART as noted in Figure 2/Table 3.

5. POWER SUPPLY
5.1. D.C. POWER FROM A POWER SUPPLY

Set the power switch SW7 to the position 2 = off.
Connect a power supply with 7-9VDC to one of the power inputs (P1 or P2).

In case of P1 use a plug with 5,5mm diameter and the positive terminal at the centre
contact.

Advertising