Philips 201B4 User Manual

Page 7

Advertising
background image

201B Product Information

SCANNING

• Horizontal scanning

30 - 115 KHz

• Vertical scanning

50 - 160 Hz

VIDEO

• Video dot rate

320 MHz

• Input impedance

- Video

75 ohm

- Sync

4.7 kOhm

• Input signal levels

0.7 Vpp

• Sync input signal

Separate sync

Composite sync

• Sync polarities

Positive and negative

WHITE COLOR TEMPERATURE

Chromaticity CIE coordinates:

• at 9300 K degrees

x = 0.283 / y = 0.297

• at 6500 K degrees

x = 0.313 / y = 0.329

• at 5500 K degrees

x = 0.332 / y = 0.347

sRGB

sRGB is a standard for ensuring correct exchange of colors between different devices (e.g. digital cameras, monitors, printers,
scanners, etc.)

Using a standard unified color space, sRGB will help represent pictures taken by an sRGB compatible device correctly on your
sRGB enabled Philips monitors. In that way, the colors are calibrated and you can rely on the correctness of the colors shown
on your screen.

Important with the use of sRGB is that the brightness and contrast of your monitor is fixed to a predefined setting as well as the
color gamut. Therefore it is important to select the sRGB setting in the monitor's OSD.

To do so, open the OSD by pressing the OK button on the front of your monitor. Use the down button to go to Color
temperature and press OK again. Then move the down button to go to sRGB and press OK again.

Exit this OSD.

After this, please don't change the brightness or contrast setting of your monitor. If you change either of these, the monitor will
exit the sRGB mode and go to a color temperature setting of 9300K.

* These information are subject to change without notice.

file:///D|/EDFU/crt_19_5/edoc/english/201B/PRODUCT/PRODUCT.HTM (2 of 5)2005-04-21 ¤W¤И 09:39:07

Advertising