Setting Up NetScout Manager Plus for FrameSaver Devices
8-14
9664-A2-GB20-00
March 2000
"
Procedure
1. Open a terminal window and go to $NSHOME/usr.
2. Copy an example or interface-specific file to a new file that contains the user
history table number.
3. Open the new file using a text editor.
The variables in the file are listed with their OIDs (Object IDs). The frame
relay interface number 101022001 must replace @IFN, and the DLCI number
to be monitored must replace @DLCI.
Example: frCircuitSentFrames
Change “
1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI
”
to “
1.3.6.1.2.1.10.32.2.1.6
.
101022001.301
”
The only valid interface number for a FrameSaver 9664 unit is 101022001.
4. Edit the new file, as needed.
Refer to
Creating .UDH Files and Using Custom History in the NetScout Manager
Plus User Guide for additional information.
SNMP MIBs and Traps, and RMON Alarm Default