Troubleshooting, cont’d.

Problems and Corrective Actions

Problem

Corrective Action

PRESSURE DROPS ON GAUGE

a. If pressure drops on gauge, shut off power to

pump and turn motor shaft with your fingers.
If it turns freely then the pump must be
disassembled and the impeller checked to see
if it is clogged. If it is not frozen or clogged then
there is an obstruction in the line between the
pool and the pump.

PRESSURE REMAINS HIGH

a. If pressure remains high after backwash -

AFTER BACKWASH

backwash filter again. If still high, treat for
conditions covered by LIMING-UP above.

MAINTAIN YOUR PRESSURE GAUGE

The pressure gauge is an important part of the

a. Check the operation of your pressure gauge

IN GOOD WORKING ORDER

filter system. It is your primary indicator of how

in the following manner:

the system is operating.

(1) The pressure gauge should go to zero (0)

when the system is turned off and pressure
is relieved.

(2) The pressure gauge should indicate pressure

when the system is operating.

(3) The pressure gauge should be readable and

not damaged in any way.

(4) Replace the pressure gauge if it is not

meeting the requirements of items
(1) through (3) of this section.

DIATOMITE IS CONTINUOUSLY

a. Inspect the elements for any tears or holes.

ENTERING THE POOL

b. Inspect the internal air bleed sock for tears

and proper installation.

c. Inspect the elements and make sure the elements

are positioned vertically and properly seated
between the upper manifold and lower manifold.