6

OUT

VIDEO

IN

OUT

VIDEO

IN

Coaxial
Cable

Coaxial Cable

Cameras

First Video
Monitor

Last Video
Monitor

Video Switcher

Connection with the Camera
Site

Connect the Video output of the camera site equipment to
the VIDEO IN connector at the rear of the monitor using a
coaxial cable.
The maximum coaxial cable length between the camera
and the monitor is shown in the table below.

Cable

CONNECTIONS

The connections described below should be made by qualified service personnel or system installers.

An example of a basic connection is shown below.

A

IN

Video Switcher

AC IN

OUT

VIDEO

IN

CCIR

EIA

Cable length

RG-59/U
3C-2V

RG-6/U
5C-2V

RG-11/U
7C-2V

RG-15/U
10C-2V

500 m

(1 650 ft)

750 m

(2 475 ft)

1 000 m

(3 300 ft)

1 250 m

(4 125 ft)

Multiple Monitor Connection

Connect the VIDEO OUT connector on the monitor to the
VIDEO IN connector of an other monitor with a coaxial
cable to monitor the same video on multiple monitors.
Up to 10 monitors in total can be connected in a series
before signal loss occurs. The total cable length should not
exceed 150 m (500 feet).