HI-TEMP GASKET
The Napoleon Model NZ6000 may be connected to either
a lined or unlined masonry chimney.
IF THE CHIMNEY IS
LINED,
the flues
must be made of vitri-
fied clay and be in
sizes of 8" square or
8" round (inside diam-
eters) or 8"x12" with a
minimum height of 15
feet above the fire-
place. Eight inch round
flues are recom-
mended. Installation
must conform to both
national and local
code requirements.
IF THE CHIMNEY IS UNLINED,
a stainless steel liner
listed to either Standard ULC-S640M in Canada or UL-
1777 in the USA: Liners for New Masonry Chimneys, may
be used to connect the fireplace to the chimney. The liner
must be continuous from the fireplace to the chimney cap
and be installed only per manufacturers instructions. In
both cases, the chimney structure must be supported by
angle iron anchored into the masonry walls. The allow-
able masonry used in chimney construction is 3-1/2" brick,
solidly mortared and fully encasing the flue. Ensure there
are no leaks.
FLUE TILE SUPPORT FOR A MASONRY FIREPLACE
FIREPLACE TOP
ANCHOR PLATE
FIREPLACE TOP
For a masonry fireplace use a flue tile support. For a pre-
fabricated chimney use an anchor plate.
In no case is the masonry
enclosure to be sup-
ported by the NZ6000 fire-
place. Allow a 1" (one inch)
air cavity for expansion.
CONNECTION TO A MASONRY CHIMNEY