7.4

Checking measurements and statistics

The parameters that can be viewed through the Q1 menus Measurement (main
menu branch 7 and Statistics (main menu branch 8) are listed below.

Measurements via Q1

Noise margin

Rx level

Tx level

Line attenuation

Line voltage (remote-powered)

Attenuation can be 0 to 41 dB.

DNT2Mi-fp statistics

Signal qualities of the selected 15-minute periods (100) and 24-hour periods (30)
and since the last reset, according to Rec. G.826, are indicated by the quality
parameters in the table below.

Monitoring a line

Tx level

Line 1 or 2: xx dBm

xx = +7.5 to +14.5 dBm

Rx level

Line 1 or 2: xx dBm

xx = +14.5 to -35 dBm

Noise margin

Line 1 or 2: xx dB

xx = 0 to +15 dB

Noise margin

+15...1 dB, expected BER < 10

-7

0 dB, expected BER 10

-7

Attenuation

Line 1 or 2: xx dB

xx = 0 to 50 dB