5.Turn gas knob counter-clockwise

to pilot.

6.Depress slightly and hold gas knob while lighting the
pilot with the push button ignitor. Keep knob depressed
for one minute, then release. If pilot does not continue to
burn, repeat steps 3 through 5.
7.With pilot lit, depress and turn gas knob counter-clock-
wise

to on.

8.If equipped with remote on-off switch/thermostat, main
burner may not come on when you turn valve to on. Re-
mote switch must be in the on position to ignite burner.
9.Turn on all electric power to the fireplace.

FLAME ADJUSTMENT

KNOB

ON/OFF KNOB

A. This fireplace is equipped with a pilot which must be lit

by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for

gas and next to the floor because some gas is heavier
than air and will settle on the floor.

C. Use only your hand to turn the gas control knob. Never

use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under water.

• Turn off all gas to the fireplace.

• Open windows.

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone
in your building.

• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire de-
partment.

When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed
slightly.
1.
Stop! Read the above safety information on this label.
2.Turn off all electric power to the fireplace.
3.Turn the gas knob clockwise

to off.

4.Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. Stop! Follow "B" in the above
safety information on this label. If you don't smell gas go
the next step.

2.Push in gas control knob slightly and turn clock-

wise

to off. DO NOT FORCE.

1.Turn off all electrical power to the unit if service is to

be performed.

TURN OFF THE GAS AND UNPLUG ELECTRI-

CAL POWER BEFORE SERVICING THE

STOVE!

CAUTION: Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing.
This insert and its venting system should be inspected
before use and at least annually by a qualified service per-
son. The fireplace area must be kept clear and free of com-
bustible materials, gasoline or other flammable vapours
and liquids. The flow of combustion and ventilation air must
not be obstructed.

1. In order to properly clean the burner and pilot assem-

bly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shut-

ter opening and the area surrounding the logs clean by
vacuuming or brushing, at least once a year.

3. Check to see that all burner ports are burning. Clean

out any of the ports which may not be burning or are not
burning properly.

4. Check to see that the pilot flame is large enough to

engulf the thermocouple on one leg and reaches toward
the burner on the other leg.

5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely

on all openings when the gas knob for the burner is turned
on. A 5-10 second total light-up period is satisfactory. If
ignition takes longer, consult your Napoleon dealer/dis-
tributor.

7. Check that the door gasketing is not broken or miss-

ing. Replace if necessary.

8. Lift the door from its hinges to clean hinge pins and

lubricate using high-temp dry graphite as necessary. Re-
place.
NOTE: Due to the high temperatures that the hinges expe-
rience, wet lubricants such as oil and WD40 will cause the
hinge to seize and are therefore not suitable.

PURGE THE GAS LINE WITH THE GLASS DOOR OPEN.

FOR YOUR SAFETY READ BEFORE LIGHTING:

WHAT TO DO IF YOU SMELL GAS

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

MAINTENANCE