W415-0098 / A / 08.07.03

Remove the pilot screw cap. Adjust the pilot screw to pro-
vide properly sized flame. Turn in a clockwise direction to
reduce the gas flow. Replace the pilot screw cap.

REAR BURNER

FRONT BURNER

AIR SHUTTERS

FIGURE 46

FIGURE 47

FIGURE 48

Air shutter adjustment
must only be done by a
qualified gas installer!

FIGURE 49

To access the venturi, remove the screw securing each
burner to the burner pan; slide to the right, lift up and out.
For the air shutter settings, see the chart below.

Closing the air shutter will cause a more yellow flame, but
can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner
ports. The flame may not appear yellow immediately; allow
15 to 30 minutes for the final flame colour to be estab-
lished.

FRONT BURNER