14

11. To disconnect

permanently

When it is necessary to disconnect the sprayer’s battery power cord from the
battery, use the following procedure:

1. Disconnect sprayer’s remote switch power cord from the battery power cord.

2. Disconnect the battery power cord from the vehicle battery as follows:

a) Disconnect vehicle battery ground wire.
b) Disconnect the battery cord’s black battery clamp or black wire

connector from the negative (-) terminal of the vehicle battery.

c) Disconnect the battery cord’s red battery clamp or red wire

connector from the positive (+) terminal of the vehicle battery.

d) Reconnect the vehicle battery ground wire.

WARNING: Always connect in this sequence to avoid possible shock.

(Remember that on some vehicle models, you may need to remove the sprayer to
access the battery)


S

tep Eight: Check and test completed assembly.

WARNING

Check and test completed assembly

Serious injury could result from chemical leaks if sprayer is improperly
assembled or the design of the sprayer is modified.

Follow the steps below to ensure the sprayer is properly assembled. Never
modify the sprayer design.

1. Check assembly

Check assembly to assure the sprayer is properly assembled and in safe
working condition:

a) Check that the gun clip screws are tight, hose clamps are secure, and tank

straps are properly fastened.

b) While it is unlikely that factory-assembled components become loose, they

should also be checked to make sure they are tight.

2. Test with water

Test the system for leaks with water:

a) First read the instructions in this Owner’s Manual for Operation of the

sprayer

b) Fill the tank with water per the instructions in this manual.

Important: The sprayer should be OFF when you fill the tank.

c) Check for leaks throughout the system by operating the sprayer per the

instructions in this manual:

i) Turn the sprayer ON. (See Operation Instructions)
ii) Operate the spray gun. (See Operation Instructions)
iii) Adjust the pressure through its full range – to maximum and back.

(See Operation Instructions)

d) If a leak is detected, fix the leak and re-test the system with water.

Advertising