Operation - Using the Sprayer (continued)

24

01542

Priming

valve lever

Priming

hose

01542

Priming valve

Step Three: Operate the sprayer.

WARNING

ALWAYS wear personal protective equipment as directed on the
chemical label when spraying.

Long pants and sleeves, chemical-resistant gloves, and eye protection are
strongly recommended. Additional protective gear may be required
depending on the particular pesticide.

1. Review safety

information

Review the “Operation – Important Safety Information” related to Chemical
Application Safety and ATV Vehicle Handling Safety provided in this manual.

2. Wear personal

protective
equipment

Wear personal protective equipment as directed on the chemical label.
Warning:
Wear additional personal protective equipment if you will be
spraying overhead or fogging. You will be exposed to much more pesticide
fallout in these applications. Wear chemical resistant head and neck protection,
full facemask or half facemask with sealed goggles, and consider using a
dust/mist respirator.

3. Open priming

valve

Turn priming valve lever so that it is in-line with the priming hose.











4. Turn on power

Turn on the power to the sprayer.

1. Verify the battery power cord is connected to the remote switch power cord

and that the remote switch power cord is connected to the pump power cord.

2. Turn the remote switch to the “ON” position.

Note: The pump will start automatically when power is turned on. Running
the pump dry will void all warranties.

5. Ensure flow

through priming
hose

Once chemical is flowing through the priming hose, close the priming valve.