Setting the SCSI ID on the Internal Scanner

The SCSI ID is set by a set of DIP switches on the back of the
internal-mount scanner as shown below. In most cases, these
DIP switches will not be changed.

If it is necessary to change the default SCSI ID, change the
position of the DIP switches to the proper SCSI ID. Refer to
Table 5.2 for the proper DIP switch values. When changing the
position of the switches, use a pointed instrument to toggle the
switch. Use of a pen or pencil is not recommended, since these
will leave a mark on the switch and make it difficult to
differentiate between the “on” and “off” positions.

SCSI ID

DIP #1

DIP #2

DIP #3

0

Open

Open

Open

1

Closed

Open

Open

2

Open

Closed

Open

3

Closed

Closed

Open

4

Open

Open

Closed

5

Closed

Open

Closed

6

Open

Closed

Closed

7

Closed

Closed

Closed

Table 5.2 SCSI ID DIP switch values