- 41 -

6. Operation

6.1

Turning on the Power

Turn the COOLSCAN II on first, the other SCSI devices next,
and the host computer last. If your scanner is the internal-
mount model, you need not turn the COOLSCAN II on.

After turning the power on, the LED will begin to blink to
indicate scanner initialization.

The scanner is self-calibrating. A calibration procedure occurs
automatically during power-up. This procedure typically takes
about twenty seconds.

Due to the patented light source, there is no warm up time
necessary for the scanner. Once the scanner has performed its
power-on calibration, it is ready to go.

Remarks

• To turn the COOLSCAN II power off, turn the host

computer off first, the other SCSI devices next, and the
COOLSCAN II last (reverse order from switching on).

• Once the power is turned off, please wait five seconds or

more before turning the power on again.

• Do not turn the power off while the scanner is scanning.
• Make sure there is no strip film holder in the scanner during

power-up, or the scanner will not calibrate correctly.

POWER ON