Nv-p2100 wiring diagram – Nuvo NV-P2100 User Manual

Page 11

Advertising
background image

NV-P2100 Wiring Diagram

11

R

L

SENSITIVITY

OdBV = 1.0RMS

-12

+6

0

LEFT

+6

-12

RIGHT

0

AUDIO

INPUT

2

INPUT

OUTPUT

CONTROL

SPEAKER

MODEL NV-P2100

HIGH EFFICIENCY 200 WATT

STEREO AMPLIFIER

NuVo Technologies Cincinnati Ohio. USA

120V

60HZ

WATTS

250

UNIT

ON

+12VDC

100mA

VOLTAGE
TRIGGER

3-30 VOLTS

AC OR DC

ON/OFF SWITCH

AUDIO

AC/DC

POWER

MODE

OUTPUT POWER

8 OHM: 70W X 2

4 OHM: 100W X 2

CONTROL

USE ONLY WITH 250V FUSE

USE ONLY WITH 250V FUSE

120V

60Hz 300W

MODELNV-E6M
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM

KUSTOMINC. CINCINNATI, OH USA

LINE OUT

L

LINE OUT / SPEAKER

LINE OUT

LINE OUT

LINE OUT

LINE OUT

LINE OUT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

20W/8 OHM X2

20W/8 OHM X2

20W/8 OHM X2

20W/8 OHM X2

20W/8 OHM X2

20W/8 OHM X2

R

L

R

L

R

L

R

L

R

L

R

LEFT

-

+

RIGHT

-

+

LEFT

-

+

RIGHT

-

+

LEFT

-

+

RIGHT

-

+

LEFT

-

+

RIGHT

-

+

LEFT

-

+

RIGHT

-

+

LEFT

-

+

RIGHT

-

+

0215

IR EMITTER OUTPUTS

+12V OUTPUT PULSE

1

2

3

4

5

6

SUM

AUDIO OUTPUT

CONNECTTONV-E6X

ODDNUMBEREDOUTPUTSAREIDENTICAL(TIEDTOGETHER)

EVENNUMBEREDOUTPUTSAREIDENTICAL(TIEDTOGETHER)

REFER TO MANUAL

0 1 2 3

DIAGNOSTIC

CONTROL

-INPUT- -OUTPUT-

MUTE UNITON

+12V G

N.O. G

1

2

3

4

5

6

INPUT SOURCES

L

R

DIGITAL OUTPUT

CONNECT TO

NV-E6X

NETWORK

CONNECTTO

NV-EZP

The NuVo P2100 has the ability to be triggered by an incoming audio signal, or by the presence of a voltage as shown in the
diagram with the NuVo Essentia system.

The variable line-out of the NuVo Essentia amplifier allow the volume to be controlled by the audio systems keypads. The best
sensitivity trim setting for this is +6.

Advertising